Kinsler Handbook #32 May 2025
Kinsler Fuel Injection, Inc, 1834 THUNDERBIRD TROY, MICHIGAN 48084 U.S.A. www.Kinsler.com Phone (248) 362-1145 Fax (248) 362-1032 184 PUMP RPM PSI TP-200 TP300 TP-350 TP-400 TP-450 TP-500 TP-700 TP-800 TP-900 TP-1100 TP-1300TP-1600TP-2300 2000 5 337 508 590 670 760 840 1170 1310 1575 1905 2241 2000 50 325 490 550 655 745 820 1160 1300 1545 1880 2230 2775 3981 3500 100 550 845 950 1120 1275 1415 2010 2265 2660 3250 3875 4815 6887 PUMP OUTPUT In theory, a mechanical pump’s output is linear to the RPM at which it is driven. Rotate the pump shaft twice as fast and the flow will double. However, even a good pump is affected by the physical clearances of the gears and the pressure load against the outlet. Typically the flows at very low RPM and very high RPM will be below the linear graph of the pump’s output due to internal leakage, pumping friction losses, and clearance in the components. Running clearance is a must for the pump gears. This clearance causes some internal leakage back past the gears and has the same effect as a bypass from the pump outlet back to the inlet. MECHANICAL FUEL PUMP TYPICAL APPLICATIONS VERSUS PUMP SIZE These recommendations are based on the pump running at 1/2 crank speed. Variations will occure with RPM of engine and pump drive speed. GENERAL SIZING AND SERVICE Engine displacement, volumetric efficiency, and the fuel being used will dictate the required pump displacement size. If you have a doubt about the size of your pump, note the number stamped on it and give us a call. Several pumps are assembled using the same size housing, so casting numbers on the housing do not indicate the exact pump displacement. Most pumps are identified by the serial number stamped, etched, or metal tag on it. Most pumps experience wear over a period of time. To maintain engine performance on a fuel system where the pump is losing flow out - put, the main jet has to be continually richened. If the main jet is not richened, the top end performance will drop off. If a problem is not found after thoroughtly checking other engine components (especially valve springs, cam lobes, and ignition), the pump should be sent in for testing. We can test and rebuild many types of pumps. To have a pump tested, send it in with all of the fittings still in it. Include a day and evening time telephone number with the area code..... a technician will call if there is a problem. Flows in this chart are in pounds per hour (lbs/hr) of .720 specific gravity test fluid at 60 o F. Tough Pump Sizes FLOWS ARE AVERAGE OUTPUT - ACTUAL OUTPUT MAY VARY SLIGHTLY ALL FLOWS , SIZES , AND RECOMMENDATIONS FOR FUEL PUMPS ARE FOR GENERAL REFERENCE. CONSULT A KINSLER TECHNICIAN FOR YOUR SPECIFIC APPLICATION !!! © 2024 TP Hilborn Typical Use 200 0 Small displacement four cylinder engine (typically) fueled by gasoline and/or alcohol 300 N/A Large displacement four cylinder engine (typically) fueled by gasoline and/or alchol 350 N/A Large displacement four cylinder engine (typically) fueled by gasoline and/or alchol 400 0 Gasoline and alcohol (typically 6-cylinder and under 400 cubic inch V8) 450 N/A Alcohol (over 400 cubic inch V8) 500 -1/2 Gasoline and alcohol (typically unblown under 430 cubic inch V8) 700 800 900 1100 -1 Unblown and blown gasoline; unblown alcohol up to 700 cubic inch displacement; small displacement blown alcohol low boost or low % nitro 1300 -2 Small displacement unblown high % nitro ; average blown alcohol 1600 -4 Large displacement unblown high % nitro; large displacement high boost blown alcohol; small displacement low boost blown nitro LB1500 -5 Very large displacement high boost blown alcohol; large displacement high boost high % nitro
RkJQdWJsaXNoZXIy ODE2MjA=